MTL7707+ MTL7700 Series DIN-rail mounting safety barriers.
The ranges have evolved over the years but the latest MTL7700 range is unique in providing a broad range of benefits that the instrumentation engineer looks for in a modern barrier.
With the MTL7700, continuing the heritage, their commitment to zener barriers is confirmed for many years to come.
Model No.
MTL | 1 Safety description | Polarities 2 available |
Application | Basic circuit Hazardous Safe | Max. end-3 to-end resistance Ω | Vwkg at 4 10µA or (1µA) V | 5 Vmax
V | Fuse6 rating
mA | ||||
V | Ω | mA | + | – | ac | |||||||
7706+ 7707+
7707P+ | 28 28 28 28 28 | 300 300 diode 164 diode | 93 93
171 – | 3 3
3 | Transmitters Switches
Transmitters, switches, controller outputs IIB |
See 'HOW THEY WORK' and 'ACTIVE / ELECTRONICALLY PROTECTED BARRIERS' |
See additional specification | 35 35 35 35 35 | 50 50 50 50 50 | |||
7710+ | 10 | 50 | 200 | 3 | 75 | 6.0 | 7.0 | 50 | ||||
7715+ | 15 | 100 | 150 | 3 | 6V dc & 4V ac systems | 119 | 12.0 | 13.1 | 100 | |||
7715P+ | 15 | 50 | 291 | 3 | 12V systems | 64 | 12.6 | 13.7 | 100 | |||
7722+ 7728+ 7728- | 22 28 28 | 150 300 300 | 147 93 93 | 3 3 |
3 | 12V dc systems 18V dc systems Controller outputs, solenoids Transmitters | 174 333 333 | 19.6 25.9 25.9 | 20.2 26.5 26.5 | 50 50 50 | ||
7728ac | 28 | 300 | 93 | Controller outputs, solenoid valves |
| 333 | 25.0 | 25.9 | 50 | |||
7728P+ | 28 | 234 | 119 | 3 | Controller outputs, solenoid valves IIB | 252 | 24.9 | 25.9 | 100 | |||
7729P+ | 28 | 164 | 170 | 3 | 184 | 24.9 | 25.9 | 100 | ||||
774X |
10 |
— |
19 | Prox sw input, solid state output and line fault detect | See 'ACTIVE / ELECTRONICALLY PROTECTED BARRIERS' |
— |
— |
30/35 |
50 | |||
7755ac |
3 3 |
10 10 |
300 300 |
3 3 |
2- or 3- Wire RTDs (floating bridge)
|
|
19.0 19.0 |
(1) (1) |
3.4 3.4 |
250 250 | ||
7756ac |
3 3 3 |
10 10 10 |
300 300 300 |
3 3 3 |
3- Wire RTDs (grounded bridge) |
|
19.0 19.0 19.0 |
(0.7) (0.7)
|
2.7 2.7
|
250 250
| ||
7758+/- | 7.5 | 10 | 750 | 3 | 3 | Gas detectors | 17 | 6.0 | 7.3 | 200 | ||
7.5 | 10 | 750 | 17 | 6.0 | 7.3 | 200 | ||||||
7761ac | 9 9 | 90 90 | 100 100 | 107 107 | 6.0 6.0 | 7.0 7.0 | 100 100 | |||||
7761Pac | 9 | 350 | 26 | 3 | Strain-gauge bridges | 378 | 6.8 | 7.5 | 50 | |||
9 | 350 | 26 | 378 | 6.8 | 7.5 | 50 | ||||||
7764+/ac | 12 | 1k | 12 | 3 | 3 | Strain-gauge bridges | 1050 | 10.0 | 10.9 | 50 | ||
12 | 1k | 12 | 1050 | 10.0 | 10.9 | 50 | ||||||
7766ac | 12 | 150 | 80 | 3 | 174 | 10.0 | 10.6 | 50 | ||||
7766Pac | 12 | 75 | 157 | Strain-gauge bridges | 92 | 9.6 | 10.5 | 100 | ||||
12 | 75 | 157 | Strain-gauge bridges | 92 | 9.6 | 10.5 | 100 | |||||
7767+ | 15 | 100 | 150 | 12V dc systems | 119 | 12.0 | 13.1 | 100 | ||||
7779+ | 28 | 300 | 93 | 3 | Controller outputs | requires channels | 333 | 25.9 | 26.5 | 50 | ||
28 | 300 | 93 | Controller outputs | separate in IIC | 333 | 25.9 | 26.5 | 50 | ||||
7796+ | 26 | 300 | 87 | 3 | Vibration probes | 333 | 23.9 | 24.5 | 50 | |||
20 | 390 | 51 | 428 | 18.3 | 18.9 | 50 | ||||||
7796- | 26 | 300 | 87 | 3 | Vibration probes | 333 | 23.9 | 24.5 | 50 | |||
20 | 390 | 51 | 428 | 18.3 | 18.9 | 50 | ||||||
7760ac | 10 | 50
| 200
| 3 | Active dc & ac sensors | 75
| 6.0
| 6.7
| 50 | |||
7765ac | 15 | 100 | 150 | 3 | 124 | 12.0 | 12.5 | 50 | ||||
15 | 100 | 150 | 124 | 12.0 | 12.5 | 50 | ||||||
7778ac | 28 | 600 | 47 | 3 | 651 | 24.0 | 25.4 | 50 | ||||
28 | 600 | 47 | 651 | 24.0 | 25.4 | 50 | ||||||
7789+ | 28
| 300
| a
| 3 |
Switch inputs / S | 651
| 26.6 26.6
| 27.2 27.2
| 50 50
| |||
7787+/- | 28 | 300 | 93 | 3 | 3 | Transmitters | 333 | 26.6 | 27.2 | 50 | ||
28 | diode | — | Controller outputs, switches | 0.9V+21Ω | 26.6 | 27.2 | 50 | |||||
7787P+ | 28 | 234 | 119 | 3 | 253 | 26.4 | 27.2 | 80 | ||||
28 | diode | — | 0.9V+21Ω | 26.4 | 27.2 | 80 | ||||||
7788+ | 28 | 300 | 93 | 3 |
| 333 | 25.9 | 26.5 | 50 | |||
10 | 50 | 200 | 3 | Transmitters | 75 | 6.0 | 7.0 | 50 | ||||
7788R+ | 28 | 300 | 93 | 3 | 333 | 25.9 | 26.5 | 50 | ||||
10 | 50 | 200 | 3 | 75 | 6.0 | 7.0 | 50 |