Product News

Discontinued MTL5000 range MTL5031 isolated barrier, the MTL5500 series model MTL5531 replace the MTL5031 barrier.

News June 24, 2020

Good quality Discontinued MTL5000 range MTL5031 isolated barrier, the MTL5500 series model MTL5531 replacement product for MTL5031.

The MTL5500 range modules are versatile yet simple to apply; use the latest technology and yet are well proven.


These contrasting attributes stem from the progression of our expertise in the design and manufacture of isolators for intrinsic safety and the application of innovative technology to achieve the required separation and segregation of the circuits.


The MTL5500 (DIN-rail mounting) and MTL4500 (backplane mounting) isolators share a common design, differing only in the mechanical mounting and connection methods.


 MTL5531 1ch vibration probe interface

MTL4531 – MTL5531 VIBRATION TRANSDUCER INTERFACE

The MTLx531 repeats a signal from a vibration sensor in a hazardous area, providing an output for a monitoring system in the safe area. The interface is compatible with 3-wire eddy-current probes and accelerometers or 2-wire current sensors; the selection is made by a switch on the side of the module.

 

SPECIFICATION

See also common specification

Number of channels

One

Sensor type

2- or 3-wire vibration transducer

Location of signal source

Zone 0, IIC, T4–6 hazardous area if suitably certified

Div. 1, Group A hazardous location

Hazardous-area input

Input impedance

(terminals 2 & 3): 10kΩ

Transducer supply current, 2-wire

3.3mA (nom.) for 2-wire sensors, user selectable by switch

Signal range

Minimum –20V, maximum –0.5V

DC transfer accuracy at 20°C

<±50mV

AC transfer accuracy at 20°C

0Hz to 1kHz: ±1%

1kHz to 10kHz: –5% to +1%

10kHz to 20kHz: –10% to +1%

Temperature coefficient

±50ppm/°C (10 to 65°C)

±100ppm/°C (–20 to 10°C)

Voltage bandwidth

–3dB at 47kHz (typical)

Phase response

<14µs, equivalent to:

–1° at 200Hz

–3° at 600Hz

–5° at 1kHz

–50° at 10kHz

–100° at 20kHz

Safe-area output impedance

<20Ω

LED indicator

Green: power indication

Supply voltage

20 to 35V dc

Maximum current consumption (10mA transducer load)

65mA at 24V

Maximum power dissipation within unit

1.33W

Safety description

Terminals 3 to 1

Uo=26.6V Io=94mA Po=0.66W Um = 253V rms or dc

Terminals 3 to 2

Non-energy-storing apparatus ≤1.5V, ≤0.1A and ≤25mW


More hot sale models these days for your reference.

MTL7728-

MTL7796-

MTL5031

MTL4850

MTL4041B

MTL4045C

MTL7796

MTL4031

MTL5516C

MTL4531

MTL7715P+

MTL5544S

MTL5510   

MTL5546

MTL5521

MTL831B    

MTL7787+

MTL7028+

MTL5544AS

MTL9377-FB-R

MTL5032

MTL4541B

MTL4575

MTL5045

MTL662-NA

MTL1372

MTL760AC

MTL760

MTL5991

MTL796-

MTL3072

MTL5544

MTL5531

MTL5575

MTL4541S

MTL4524S

MTL5541

MTL4517

MTL5546

MTL5522

MTL5521

MTL MCK45

MTL5018AC

MTL4526

MTL5544AS

MTL5549Y

MTL7755AC

MTL9466-ET

MTL2213

MTL4541

MTL3011

MTL4544A

MTL4046C

MTL4851

MTL4852

MTL665B

MTL4546

MTL4514

MTL7765AC

MTL662

MTL686

MTL5042

MTL4017

MTL2314B

MTL5544D

MTL4546Y

MTL4504

MTL3013

MTL5044

MTL3046B

MTL5018

MTL5073

MTL5045

MTL5011B

MTL5082

MTL4544S

MTL5581

MTL4541B

MTL4787P+

MTL4760AC

MTL4755AC

MTL4728+

MTL4796-

MTL5546

MTL7779+

MTL7761AC

MTL7755AC

MTL2213

MTL5511

MTL5514

MTL4516

MTL4841

MTL7715+

MTL4576-RTD

MTL787S+

MTL5040

MTL4706+

MTL5045

MTL4523VL

MTL5523VL

MTL4501-SR

MTL FP32

MTL5501-SR

MTL F253-IS

MTL5501-SR

MTL5573

MTL787SP+

MTL5314

MTL4549Y

MTL4046C

MTL4541

MTL2210B

MTL9493-PS-C9

MTL3054

MTL684

MTL764AC

MTL755AC

MTL760AC

MTL728

MTL779

MTL5991

MTL787S

MTL3045

MTL-9491-PS

MTL5053

MTL5995

MTL4573

MTL662

MTL MA10/D/2

MTL MA05/D/2

MTL5525


For any question about our Discontinued MTL5000 range MTL5031 isolated barrier, please feel free to contact me here.