Product News

International Supplier for MTL5544S REPEATER POWER SUPPLY 2-channel isolated barrier MTL5544S for sale.

News June 24, 2020

International Supplier for MTL5544S REPEATER POWER SUPPLY 2-channel isolated barrier MTL5544S with very good price for you.

Improving upon the widely adopted, enormously successful, "industry standard" MTL4000 range was a big challenge but the innovative MTL4500 range includes several new features for backplane mounting isolating interfaces. This new family easily integrates with the I/O equipment of all major instrumentation and DCS suppliers in the same secure manner as its predecessor.


MTL4544/S – MTL5544/S REPEATER POWER SUPPLY 2-channel, 4/20mA, HART®, 2- or 3- wire transmitters

The MTLx544 provides fully-floating dc supplies for energising two conventional 2-wire or 3-wire 4/20mA or HART transmitters located in a hazardous area, and repeats the current in other circuits to drive two safe-area loads. For smart transmitters, the unit allows bi-directional transmission of digital communication signals superimposed on the 4/20mA loop current. Alternatively, the MTLx544S acts as a current sink for a safe-area connection rather than driving a current into the load. Separately powered current sources, such as 4-wire transmitters, can be connected but will not support HART communication.

MTL5500 Series Barriers

Part Number

MTL5501-SR, MTL5510, MTL5510B, MTL5511, MTL5513, MTL5514, MTL5514D, MTL5516C, MTL5517, MTL5521, MTL5522, MTL5523, MTL5523V, MTL5523VL, MTL5524, MTL5525, MTL5526, MTL5531, MTL5532, MTL5533, MTL5541, MTL5541A, MTL5541AS, MTL5541S, MTL5544, MTL5544A, MTL5544AS, MTL5544D, MTL5544S, MTL5546, MTL5546Y, MTL5549, MTL5549Y, MTL5561, MTL5575, MTL5576-RTD, MTL5576-THC, MTL5581, MTL5582

MTL5544 isolated barrier


MTL5500 series

Part NumberDescription

Digital Input  

MTL5501-SR 1ch DI failsafe solid-state output + LFD alarm

MTL55104ch DI solid-state ouput

MTL5510B4ch DI multifunction solid-state output

MTL55111ch DI relay output

MTL5513 2ch DI solid-state output

MTL5514 1ch DI relay output + LFD alarm

MTL5514D 1ch switch/prox input, dual output relay 

MTL5516C2ch DI with changeover relay output

MTL55172ch DI relay output + LFD alarm

Digital Output 

MTL5521Loop powered solenoid driver, IIC 

MTL5522 Loop powered solenoid driver, IIB  

MTL5523Solenoid driver with LFD 

MTL5523V - VL Solenoid/Alarm driver with voltage control 

MTL5524 Switch operated solenoid driver 

MTL5525Loop powered solenoid driver low power 

MTL55262ch switch operated relay   

Analogue Input 

MTL55411ch 2/3 wire Transmitter repeater 

MTL5541A 1ch Transmitter repeater, passive input

MTL5541AS1ch Transmitter repeater, passive input, current sink

MTL5541S1ch 2/3 wire Transmitter repeater, current sink 

MTL5544 2ch 2/3 wire Transmitter repeater 

MTL5544A 2ch Transmitter repeater, passive input 

MTL5544AS 2ch Transmitter repeater, passive input, current sink

MTL5544D1ch 2/3 wire Transmitter repeater, dual output

MTL5544S2ch 2/3 wire Transmitter repeater, current sink

Analogue Output 

MTL55461ch 4-20mA smart isolating driver + LFD

MTL5546Y 1ch 4-20mA smart isolating driver + oc LFD 

MTL55492ch 4-20mA smart isolating driver + LFD 

MTL5549Y2ch 4-20mA smart isolating driver + oc LFD

Temperature Input  

MTL55751ch Temperature converter, RTD / THC with alarm

MTL5576-RTD2ch Temperature converter, RTD 

MTL5576-THC2ch Temperature converter, THC 

MTL55811ch mV/THC isolator for low-level signals

MTL55821ch resistance isolator 

Pulse and Vibration  

MTL5531 1ch vibration probe interface

MTL5532 1ch pulse isolator, digital or analogue output

MTL55332ch vibration probe interface

Fire and Smoke  

MTL5561 2ch loop-powered, for fire and smoke detectors   

General  

MPA5500 85 - 265V ac power adaptor

MTL5599Dummy isolator 

MTL599124V dc power supply