MTL5544AS 2 channel Transmitter repeater, passive input, current sink
MTL4544A/AS – MTL5544A/AS CURRENT REPEATER 4/20mA passive i/p for HART® transmitters The MTLx544A provides an input for separately powered 4/20mA transmitters and also allows bi–directional transmission of HART communication signals superimposed on the 4/20mA loop current, so that the transmitter can be interrogated either from the operator station or by a hand-held communicator (HHC). Alternatively, the MTLx544AS acts as a current sink for a safe-area connection rather than driving a current into the load.
SPECIFICATION
See also common specification
Number of channels
Two
Location of transmitter
Zone 0, IIC, T4–6 hazardous area if suitably certified
Div.1, Group A, hazardous loc ation
Hazardous area input
Signal range: 4 to 20mA
Under/over-range: 1.0 to 21.5mA
Input impedance for HART signals
at terminals 1, 2 and 4, 5: > 230Ω
Maximum input volt drop
at terminals 1, 2 and 4, 5: < 6.6V
i.e. a transmitter load of 330Ω at 20mA
Safe-area output
Signal range: 4 to 20mA
Under/over-range: 1.0 to 21.5mA
Safe-area load resistance (MTL5544A)
Conventional transmitters: 0 to 360Ω
Smart transmitters: 250Ω ±10%
Safe-area load (MTL5544AS)
Current sink: 600Ω max.
Maximum voltage source: 24V DC
Safe-area circuit output resistance: > 1MΩ
Safe–area circuit ripple
< 50µA peak-to-peak up to 80kHz
Transfer accuracy at 20°C
Better than 20µA
Temperature drift
< 1µA/°C
Response time
Settles within 200µA of final value after 20ms
Communications supported
HART
LED indicator
Green: power indication
Power requirement (with 20mA signal)
70mA at 24V
85mA at 20V
50mA at 35V
Power dissipation within unit (with 20mA signals)
MTLx544A 1.5W @ 24V dc
MTLx544AS 2.0W @ 24V dc
Safety description
Terminals 1 to 2 and 4 to 5:
Um = 253V rms or dc.
8.6V (diode). This voltage must be considered when calculating
the load capacitance.
Non-energy-storing apparatus ≤1.5V, ≤0.1A and ≤25mW; can be
connected without further certification into any IS loop with an opencircuit
voltage < 28V
MTL5500 Series Barriers
Part Number
MTL5501-SR, MTL5510, MTL5510B, MTL5511, MTL5513, MTL5514, MTL5514D, MTL5516C, MTL5517, MTL5521, MTL5522, MTL5523, MTL5523V, MTL5523VL, MTL5524, MTL5525, MTL5526, MTL5531, MTL5532, MTL5533, MTL5541, MTL5541A, MTL5541AS, MTL5541S, MTL5544, MTL5544A, MTL5544AS, MTL5544D, MTL5544S, MTL5546, MTL5546Y, MTL5549, MTL5549Y, MTL5561, MTL5575, MTL5576-RTD, MTL5576-THC, MTL5581, MTL5582
MTL5500 series
Part NumberDescription
Digital Input
MTL5501-SR 1ch DI failsafe solid-state output + LFD alarm
MTL55104ch DI solid-state ouput
MTL5510B4ch DI multifunction solid-state output
MTL55111ch DI relay output
MTL5513 2ch DI solid-state output
MTL5514 1ch DI relay output + LFD alarm
MTL5514D 1ch switch/prox input, dual output relay
MTL5516C2ch DI with changeover relay output
MTL55172ch DI relay output + LFD alarm
Digital Output
MTL5521Loop powered solenoid driver, IIC
MTL5522 Loop powered solenoid driver, IIB
MTL5523Solenoid driver with LFD
MTL5523V - VL Solenoid/Alarm driver with voltage control
MTL5524 Switch operated solenoid driver
MTL5525Loop powered solenoid driver low power
MTL55262ch switch operated relay
Analogue Input
MTL55411ch 2/3 wire Transmitter repeater
MTL5541A 1ch Transmitter repeater, passive input
MTL5541AS1ch Transmitter repeater, passive input, current sink
MTL5541S1ch 2/3 wire Transmitter repeater, current sink
MTL5544 2ch 2/3 wire Transmitter repeater
MTL5544A 2ch Transmitter repeater, passive input
MTL5544AS 2ch Transmitter repeater, passive input, current sink
MTL5544D1ch 2/3 wire Transmitter repeater, dual output
MTL5544S2ch 2/3 wire Transmitter repeater, current sink
Analogue Output
MTL55461ch 4-20mA smart isolating driver + LFD
MTL5546Y 1ch 4-20mA smart isolating driver + oc LFD
MTL55492ch 4-20mA smart isolating driver + LFD
MTL5549Y2ch 4-20mA smart isolating driver + oc LFD
Temperature Input
MTL55751ch Temperature converter, RTD / THC with alarm
MTL5576-RTD2ch Temperature converter, RTD
MTL5576-THC2ch Temperature converter, THC
MTL55811ch mV/THC isolator for low-level signals
MTL55821ch resistance isolator
Pulse and Vibration
MTL5531 1ch vibration probe interface
MTL5532 1ch pulse isolator, digital or analogue output
MTL55332ch vibration probe interface
Fire and Smoke
MTL5561 2ch loop-powered, for fire and smoke detectors
General
MPA5500 85 - 265V ac power adaptor
MTL5599Dummy isolator
MTL599124V dc power supply
Latest News
- England origin MTL4500 range MTL4575 MTL5575 TEMPERATURE CONVERTER barriers in stock for sale. We have good price for MTL4575 MTL5575 barriers.… September 15, 2023
- New arrival MTL4531 VIBRATION TRANSDUCER INTERFACE barrier products in stock at Sunup. Stock MTL4531 barrier England origin products for sale now.… September 15, 2023
- Good quality MTL4546 / MTL4546C / MTL4546Y barriers in stock for sale. We supply England origin MTL4546C barriers with competitive price.… September 15, 2023