Product News

In stock MTL5541 isolated barriers. Our new arrival MTL5541 barrier made in England products manufacturered in 2021 year for sale.

News March 05, 2021

New arrival MTL5541 barriers large quantity in stock for sale in Sunup! MTL5500 range MTL5541 one channel barriers with Eaton MTL factory new packing.

For more information about MTL5541 isolated barrier, please feel free to send me an email to Diana@sunupauto.com.


MTL5541 isolator in stock

MTL5541 barriers product introduction:

MTL4541/S – MTL5541/S REPEATER POWER SUPPLY 4/20mA, HART®, 2- or 3-wire transmitters The MTLx541 provides a fully-floating dc supply for energising a conventional 2- or 3-wire 4/20mA transmitter, which is located in a hazardous area, and repeats the current in another floating circuit to drive a safe-area load. For HART 2-wire transmitters, the unit allows bi-directional communications signals superimposed on the 4/20mA loop current. Alternatively, the MTLx541S acts as a current sink for a safe-area connection rather than driving a current into the load. Separately powered current sources, such as 4-wire transmitters, can be connected but will not support HART communication.

SPECIFICATION

See also common specification

Number of channels

One

Location of transmitter

Zone 0, IIC, T4–6 hazardous area if suitably certified

Div. 1, Group A hazardous location

Safe-area output

Signal range: 4 to 20mA

Under/over-range: 0 to 24mA

Safe-area load resistance (MTLx541)

@ 24mA: 0 to 360Ω

@ 20mA: 0 to 450Ω

Safe-area load (MTLx541S)

Current sink: 600Ω max.

Maximum voltage source: 24V dc

Safe-area circuit output resistance: > 1MΩ

Safe-area circuit ripple

< 50µA peak-to-peak

Hazardous-area input

Signal range: 0 to 24mA (including over-range)

Transmitter voltage: 16.5V at 20mA

Transfer accuracy at 20°C

Better than 15µA

Temperature drift

< 0.8µA/°C

Response time

Settles to within 10% of final value within 50µs

Communications supported

HART (terminals 1 & 2 only)

LED indicator

Green: power indication

Maximum current consumption (with 20mA signal)

51mA at 24V

Power dissipation within unit (with 20mA signal)

MTLx541 0.7W @ 24V dc

MTLx541S 1.0W @ 24V dc

Safety description

Terminals 2 to 1 and 3:

Uo=28V Io=93mA Po=651mW Um = 253V rms or dc

Terminals 1 to 3:

Simple apparatus ≤1.5V, ≤0.1A and ≤25mW; can be connected

without further certification into any IS loop with an open-circuit

voltage <28V


MTL5541 isolated barrier with factory new packing for sale.


MTL5541 isolated barrier

More hot sale product models for MTL5500 range for sale.


MTL5500 Series Barriers

Part Number

MTL5501-SR, MTL5510, MTL5510B, MTL5511, MTL5513, MTL5514, MTL5514D, MTL5516C, MTL5517, MTL5521, MTL5522, MTL5523, MTL5523V, MTL5523VL, MTL5524, MTL5525, MTL5526, MTL5531, MTL5532, MTL5533, MTL5541, MTL5541A, MTL5541AS, MTL5541S, MTL5544, MTL5544A, MTL5544AS, MTL5544D, MTL5544S, MTL5546, MTL5546Y, MTL5549, MTL5549Y, MTL5561, MTL5575, MTL5576-RTD, MTL5576-THC, MTL5581, MTL5582



MTL5500 series

Part NumberDescription

Digital Input  

MTL5501-SR 1ch DI failsafe solid-state output + LFD alarm

MTL55104ch DI solid-state ouput

MTL5510B4ch DI multifunction solid-state output

MTL55111ch DI relay output

MTL5513 2ch DI solid-state output

MTL5514 1ch DI relay output + LFD alarm

MTL5514D 1ch switch/prox input, dual output relay 

MTL5516C2ch DI with changeover relay output

MTL55172ch DI relay output + LFD alarm

Digital Output 

MTL5521Loop powered solenoid driver, IIC 

MTL5522 Loop powered solenoid driver, IIB  

MTL5523Solenoid driver with LFD 

MTL5523V - VL Solenoid/Alarm driver with voltage control 

MTL5524 Switch operated solenoid driver 

MTL5525Loop powered solenoid driver low power 

MTL55262ch switch operated relay   

Analogue Input 

MTL55411ch 2/3 wire Transmitter repeater 

MTL5541A 1ch Transmitter repeater, passive input

MTL5541AS1ch Transmitter repeater, passive input, current sink

MTL5541S1ch 2/3 wire Transmitter repeater, current sink 

MTL5544 2ch 2/3 wire Transmitter repeater 

MTL5544A 2ch Transmitter repeater, passive input 

MTL5544AS 2ch Transmitter repeater, passive input, current sink

MTL5544D1ch 2/3 wire Transmitter repeater, dual output

MTL5544S2ch 2/3 wire Transmitter repeater, current sink

Analogue Output 

MTL55461ch 4-20mA smart isolating driver + LFD

MTL5546Y 1ch 4-20mA smart isolating driver + oc LFD 

MTL55492ch 4-20mA smart isolating driver + LFD 

MTL5549Y2ch 4-20mA smart isolating driver + oc LFD

Temperature Input  

MTL55751ch Temperature converter, RTD / THC with alarm

MTL5576-RTD2ch Temperature converter, RTD 

MTL5576-THC2ch Temperature converter, THC 

MTL55811ch mV/THC isolator for low-level signals

MTL55821ch resistance isolator 

Pulse and Vibration  

MTL5531 1ch vibration probe interface

MTL5532 1ch pulse isolator, digital or analogue output

MTL55332ch vibration probe interface

Fire and Smoke  

MTL5561 2ch loop-powered, for fire and smoke detectors   

General  

MPA5500 85 - 265V ac power adaptor

MTL5599Dummy isolator 

MTL599124V dc power supply